LV200 Bioluminescence Microscope

Bioluminescence imaging has been used in a range of research fields over the past decades. Despite its advantages of very low background, high S/N ratios and an extended linear detection range, luminescence imaging with traditional microscopes has suffered from low image resolution and long exposure times. These drawbacks have limited its use and kept bioluminescence in the shadow of fluorescence imaging. With its unique optical design, the LV200 microscope takes full advantage of bioluminescence and provides the capability to acquire images with unrivalled brightness, high resolution and convenience.
Product Image

Specifications

LV200 Bioluminescence System

Observation Methods Luminescence, brightfield, transmitted fluorescence
Main Unit Light-tight enclosure
Manual focus and XY stage
Motorized excitation/emission filter wheels with 3/6 positions for standard 25 mm optical filters
Condenser for brightfield and transmitted fluorescence
Optical components optimized for low light imaging.

Accessories and Options

Illumination External halogen lamp coupled to condenser via liquid light guide.
Objectives

The following Olympus UIS2 objectives are recommended for best image flatness and illumination:

UPLSAPO 10X2 NA 0.4 WD 3.1 FN 26.5
UPLFLN 10X2 NA 0.3 WD 10 FN 26.5
UPLSAPO 20X NA 0.75 W.D. 0.6 FN 26.5
UPLFLN 40XO NA 1.3 WD 0.2 FN 26.5
LUCPLFLN 20X NA 0.45 WD 6.6-7.8 FN 22
LUCPLFLN 40X NA 0.6 WD 2.7-4 FN 22
Additional objectives are currently being evaluated.
Controller IX-UCB Controller for filter wheels and shutter.
Environmental Control Stage top incubator with temperature/gas controller and attachments for 35 mm dishes or chamber slides. Accessories include temperature feedback sensor lids for 35 mm dishes and chamber slides as well as a perfusion lid for 35 mm dishes.
Camera Options

Depending on application and required sensitivity cooled CCD cameras, EM-CCD cameras or deep cooled slow scan CCD cameras can be used. Recommended cameras are:

Hamamatsu ImagEM®* EMCCD camera designed for low to ultra-low light imaging (use with cellSens®*).
Andor iKonM™* High sensitivity CCD camera designed for low light imaging (use with MetaMorph®).
Please ask for camera/software compatibility.
Microscope table ca. 700(H) x 600(D) mm (required for large EMCCD or sCMOS cameras).
Power Consumption Main unit 850 VA
Controller 840 VA
Installation Space ca. 1500(W) x 750(D) mm (depending on configuration)
Computer Imaging computer should to meet requirements for cellSens or MetaMorph. Suggested specifications: Intel® Core 2Duo, i5 or i7, 3GHz, 4GB RAM, 160GB and 500GB hard disks, 1280x1024 display, USB, Serial RS232 and FireWire ports.
Software The motorized components and cameras can be controlled by either cellSens or MetaMorph software (depending on camera). These software packages offer advanced graphical interfaces for image acquisition, multi-dimensional image processing and analysis.

cellSens, LV200, Andor iKonM and Hamamatsu ImagEM are not for clinical diagnostic use.
MetaMorph is a registered trademark of Molecular Devices, Inc.
Hamamatsu ImagEM is a registered trademark of Hamamatsu Photonics
Andor and iKonM are trademarks of Andor Technology plc.
Intel is a registered trademark of the Intel Corporation

  • BX3 fits meDP80
  • special promoLV200
  • VS120 Slide Systemfvmpe_rs
  • Specialty Objectives Imaris by Bitplane
  • CX22cellsens Digital Imaging Software